Skip to Main Content (Press Enter)

Logo HUMANITAS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze

UNI-FIND
Logo HUMANITAS

|

UNI-FIND

hunimed.eu
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze
  1. Pubblicazioni

Diagnostic accuracy and safety of EUS-guided end-cutting fine-needle biopsy needles for tissue sampling of abdominal and mediastinal lymphadenopathies: a prospective multicenter series

Articolo
Data di Pubblicazione:
2023
Abstract:
Background and aims: The role of the newer EUS fine-needle biopsy needles in lymphadenopathies (LAs) is still under evaluation. We aimed to evaluate the diagnostic accuracy and adverse event rate of EUS-guided fine-needle biopsy sampling (EUS-FNB) in diagnosing LAs. Methods: From June 2015 to June 2022, all patients referred to 4 institutions for EUS-FNB of mediastinal and abdominal LAs were enrolled. Twenty-two-gauge Franseen tip or 25-gauge fork-tip needles were used. The criterion standard for positive results was surgery or imaging and clinical evolution over a follow-up of at least 1 year. Results: One hundred consecutive patients were enrolled, consisting of those with a new diagnosis of LA (40%), presence of LA with a previous history of neoplasia (51%), or suspected lymphoproliferative disease (9%). EUS-FNB was technically feasible in all LA patients with 2 to 3 passes (mean, 2.62 ± .93). The overall sensitivity, positive predictive value, specificity, negative predictive value, and accuracy for EUS-FNB were 96.20%, 100%, 100%, 87.50%, and 97.00%, respectively. Histologic analysis was feasible in 89% of cases. Cytologic evaluation was performed in 67% of specimens. A statistical difference between the accuracy of the 22-gauge or 25-gauge needle (P = .63) was not found. A subanalysis on lymphoproliferative disease revealed a sensitivity and accuracy of 89.29% and 90.0%, respectively. No adverse events were recorded. Conclusions: EUS-FNB with new end-cutting needles is a valuable and safe method to diagnose LAs. The high quality of histologic cores and the good amount of tissue allowed a complete immunohistochemical analysis of metastatic LAs and precise subtyping of the lymphomas. (Clinical trial registration number: NCT02855151.).
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Carrara, Silvia; Rahal, Daoud; Khalaf, Kareem; Rizkala, Tommy; Koleth, Glenn; Bonifacio, Cristiana; Andreozzi, Marta; Mangiavillano, Benedetto; Auriemma, Francesco; Bossi, Paola; Balzarotti, Monica; Facciorusso, Antonio; Staiano, Teresa; Maldi, Elena; Spadaccini, Marco; Colombo, Matteo; Fugazza, Alessandro; Maselli, Roberta; Hassan, Cesare; Repici, Alessandro
Autori di Ateneo:
Carrara Silvia
Hassan Cesare
Mangiavillano Benedetto
Maselli Roberta
Repici Alessandro
Link alla scheda completa:
https://iris.hunimed.eu/handle/11699/86825
Pubblicato in:
GASTROINTESTINAL ENDOSCOPY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.9.3.0