Lung stress and strain during mechanical ventilation : any safe threshold?

Articolo
Data di Pubblicazione:
2011
Abstract:
RATIONALE: Unphysiologic strain (the ratio between tidal volume and functional residual capacity) and stress (the transpulmonary pressure) can cause ventilator-induced lung damage.
OBJECTIVES: To identify a strain-stress threshold (if any) above which ventilator-induced lung damage can occur.
METHODS: Twenty-nine healthy pigs were mechanically ventilated for 54 hours with a tidal volume producing a strain between 0.45 and 3.30. Ventilator-induced lung damage was defined as net increase in lung weight.
MEASUREMENTS AND MAIN RESULTS: Initial lung weight and functional residual capacity were measured with computed tomography. Final lung weight was measured using a balance. After setting tidal volume, data collection included respiratory system mechanics, gas exchange and hemodynamics (every 6 h); cytokine levels in serum (every 12 h) and bronchoalveolar lavage fluid (end of the experiment); and blood laboratory examination (start and end of the experiment). Two clusters of animals could be clearly identified: animals that increased their lung weight (n = 14) and those that did not (n = 15). Tidal volume was 38 ± 9 ml/kg in the former and 22 ± 8 ml/kg in the latter group, corresponding to a strain of 2.16 ± 0.58 and 1.29 ± 0.57 and a stress of 13 ± 5 and 8 ± 3 cm H(2)O, respectively. Lung weight gain was associated with deterioration in respiratory system mechanics, gas exchange, and hemodynamics, pulmonary and systemic inflammation and multiple organ dysfunction.
CONCLUSIONS: In healthy pigs, ventilator-induced lung damage develops only when a strain greater than 1.5-2 is reached or overcome. Because of differences in intrinsic lung properties, caution is warranted in translating these findings to humans.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Healthy lung; Lung strain; Lung stress; Tidal volume; Ventilator-induced lung injury
Elenco autori:
Protti, A.; Cressoni Mainoni, M. T.; Santini, A.; Langer, T.; Mietto, C.; Febres, D.; Chierichetti, M.; Coppola, S.; Conte, G.; Gatti, S.; Leopardi, O.; Masson, S.; Lombardi, L.; Lazzerini, M.; Rampoldi, E.; Cadringher, P.; Gattinoni, L.
Autori di Ateneo:
Protti Alessandro
Santini Alessandro
Link alla scheda completa:
https://iris.hunimed.eu/handle/11699/73892
Pubblicato in:
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE