Investigation on the role of integrated PET/MRI for target volume definition and radiotherapy planning in patients with high grade glioma
Articolo
Data di Pubblicazione:
2014
Abstract:
Purpose To evaluate the impact of fluid-attenuated-inversion-recovery MRI (FLAIR/MRI) and Carbon-11-labeled-methionine PET (11C-MET-PET) on high grade glioma (HGG) tumor volume delineation for radiotherapy planning. Material and methods Sixty-nine patients with HGG were evaluated. The clinical target volumes (CTV1, generated by adding a 10 mm margin to FLAIRMRI area, CTV2 by adding a 20 mm margin to enhanced T1MRI) and biological target volume (BTV) were delineated on pre-operative MRI images and 11CMETPET respectively. Results The overlap between CTV1 and CTV2 showed a low correlation between the two volumes with CTV1 not always fully included into the CTV2. In all cases the whole BTV was included into the CTV1, while in 35/69 patients (50%) part of BTV was outside the CTV2 despite larger margins were added. In all cases recurrences were within the CTV1 volume and in 19/38 (50%) partially outside the CTV2. In all patients relapse corresponded to the BTV area. Conclusions Our data suggest that the target volume definition using FLAIR-MRI is more adequate compared to enhanced T1MRI. 11C-METPET uptake could help identify microscopic residual areas.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
High grade glioma; MET-PET; Radiotherapy-planning;
Elenco autori:
Navarria, P.; Reggiori, G.; Pessina, F.; Ascolese, A. M.; Tomatis, S.; Mancosu, P.; Lobefalo, F.; Clerici, E.; Lopci, E.; Bizzi, A.; Grimaldi, M.; Chiti, A.; Simonelli, M.; Santoro, A.; Bello, L.; Scorsetti, M.
Link alla scheda completa:
Pubblicato in: