Skip to Main Content (Press Enter)

Logo HUMANITAS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze

UNI-FIND
Logo HUMANITAS

|

UNI-FIND

hunimed.eu
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze
  1. Pubblicazioni

Changes in shunt, ventilation/perfusion mismatch, and lung aeration with PEEP in patients with ARDS: a prospective single-arm interventional study

Articolo
Data di Pubblicazione:
2020
Abstract:
Background: Several studies have found only a weak to moderate correlation between oxygenation and lung aeration in response to changes in PEEP. This study aimed to investigate the association between changes in shunt, low and high ventilation/perfusion (V/Q) mismatch, and computed tomography-measured lung aeration following an increase in PEEP in patients with ARDS.Methods: In this preliminary study, 12 ARDS patients were subjected to recruitment maneuvers followed by setting PEEP at 5 and then either 15 or 20 cmH(2)O. Lung aeration was measured by computed tomography. Values of pulmonary shunt and low and high V/Q mismatch were calculated by a model-based method from measurements of oxygenation, ventilation, and metabolism taken at different inspired oxygen levels and an arterial blood gas sample.Results: Increasing PEEP resulted in reduced values of pulmonary shunt and the percentage of non-aerated tissue, and an increased percentage of normally aerated tissue (p < 0.05). Changes in shunt and normally aerated tissue were significantly correlated (r = -0.665, p = 0.018). Three distinct responses to increase in PEEP were observed in values of shunt and V/Q mismatch: a beneficial response in seven patients, where shunt decreased without increasing high V/Q; a detrimental response in four patients where both shunt and high V/Q increased; and a detrimental response in a patient with reduced shunt but increased high V/Q mismatch. Non-aerated tissue decreased with increased PEEP in all patients, and hyperinflated tissue increased only in patients with a detrimental response in shunt and V/Q mismatch.Conclusions: The results show that improved lung aeration following an increase in PEEP is not always consistent with reduced shunt and V/Q mismatch. Poorly matched redistribution of ventilation and perfusion, between dependent and non-dependent regions of the lung, may explain why patients showed detrimental changes in shunt and V/Q mismatch on increase in PEEP, despite improved aeration.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
ARDS; CT; Lung aeration; PEEP; Shunt; Ventilation/perfusion mismatch; Adult; Aged; Blood Gas Analysis; Female; Humans; Male; Middle Aged; Positive-Pressure Respiration; Prospective Studies; Respiratory Distress Syndrome; Tomography, X-Ray Computed; Ventilation-Perfusion Ratio
Elenco autori:
Karbing, Dan Stieper; Panigada, Mauro; Bottino, Nicola; Spinelli, Elena; Protti, Alessandro; Rees, Stephen Edward; Gattinoni, Luciano
Autori di Ateneo:
Protti Alessandro
Link alla scheda completa:
https://iris.hunimed.eu/handle/11699/61544
Pubblicato in:
CRITICAL CARE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.9.3.0