Skip to Main Content (Press Enter)

Logo HUMANITAS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze

UNI-FIND
Logo HUMANITAS

|

UNI-FIND

hunimed.eu
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Competenze
  1. Pubblicazioni

Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences

Articolo
Data di Pubblicazione:
2014
Abstract:
PURPOSE:
The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up.
METHODS:
Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90° flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up.
RESULTS:
There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs.
CONCLUSION:
Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years.
LEVEL OF EVIDENCE:
III.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Antero-stabilized knee; Kinematics; Navigation; Postero-stabilized knee; Total knee arthroplasty; Aged; Aged; 80 and over; Arthroplasty; Replacement; Knee; Biomechanical Phenomena; Female; Femur; Humans; Joint Instability; Knee Prosthesis; Male; Middle Aged; Osteoarthritis; Knee; Posterior Cruciate Ligament; Range of Motion; Articular; Retrospective Studies; Rotation; Tibia; Orthopedics and Sports Medicine; Surgery; Medicine (all)
Elenco autori:
Bignozzi, Simone; Zaffagnini, Stefano; Akkawi, Ibrahim; Marko, Tedi; Bruni, Danilo; Neri, MARIA PIA; Colle, Francesca; Marcacci, Maurilio
Link alla scheda completa:
https://iris.hunimed.eu/handle/11699/31576
Pubblicato in:
KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY
Journal
  • Dati Generali

Dati Generali

URL

http://link.springer.de/link/service/journals/00167/index.htm
  • Utilizzo dei cookie